Thermal cycler calibration & PCR verification in Miami, Florida & Puerto Rico
On-site thermal cycler calibration for ABI 9700, Veriti, SimpliAmp, ProFlex and Eppendorf systems. We verify block temperature accuracy, well-to-well uniformity and applicable functional performance, then document the results for your laboratory records.
Request thermocycler verificationCall 305.238.5326Thermal cycler calibration near you
We calibrate PCR thermal cyclers on-site, so your instruments never leave the lab. South Florida (Miami-Dade, Broward and Palm Beach) is usually same-day or next-day. In Tampa Bay, Orlando and Southwest Florida, a technician can often be on site the next day and within 72 hours at most. Puerto Rico is served on planned service trips, so call 305.238.5326 to get on the next visit.
Thermal cycler calibration pricing
Per unit
Starting from $490.00 per thermal cycler. On-site block temperature accuracy and well-to-well uniformity verification, with as-found and as-left results and a report for your records.
Multiple instruments
Several thermal cyclers, or pipettes, centrifuges and thermometers on the same visit, share one trip and one schedule.
Parts
Repairs and parts are quoted separately.
Verification that shows exactly what was tested.
Each scope is matched to the instrument’s block configuration, agreed set points and the verification your laboratory needs. We document measured results and any out-of-limit findings clearly, rather than reducing a complex instrument to a generic pass statement.
Send the manufacturer, model, serial number, block configuration, instrument count and location. This lets us confirm the test setup and plan a service visit that fits your molecular schedule.
Manufacturers and models we calibrate
Block temperature uniformity, ramp rate, and timer accuracy — verified with NIST-traceable references and documented for CLIA and CAP review. Common platforms include:
Applied Biosystems
Veriti and Veriti Pro, SimpliAmp, GeneAmp 9700 single-head and dual-head, ProFlex and comparable systems.
Life Technologies
SimpliAmp, Veriti Pro, and legacy GeneAmp platforms — now part of the Thermo Fisher family, serviced the same.
Eppendorf
Mastercycler, Mastercycler Nexus, X50 and ep gradient series.
Models we see most often
Veriti Pro
Multi-zone block verification across all six zones, plus ramp and timer accuracy.
SimpliAmp
Block uniformity and heated-lid verification with as-found and as-left data.
GeneAmp 9700 — single head
Block temperature accuracy and uniformity verification on the classic single-block configuration.
GeneAmp 9700 — dual head
Both blocks verified and reported independently — never averaged across heads.
Eppendorf Mastercycler
Block, gradient and lid verification across the Mastercycler range.
Other platforms
Bio-Rad, Techne, Analytik Jena and comparable cyclers — send us the model.
Every calibration leaves behind a NIST-traceable certificate, a dated calibration label on the instrument, and records organized the way a surveyor expects to see them.
Even, accurate blocks — reproducible runs
Using NIST-traceable temperature probes, BMCA verifies block accuracy and well-to-well uniformity, performs preventive maintenance, and documents the result — protecting the molecular work your lab depends on.
Why it matters
Molecular results are only as trustworthy as the thermal cycling behind them. Calibrated, maintained instruments protect both your data and your accreditation.
Service includes
- Block temperature accuracy at set points
- Well-to-well uniformity mapping
- Ramp/function verification as applicable
- Preventive maintenance & cleaning
- NIST-traceable certificate
- Dated label & service record
Built for the facilities we serve
Molecular labs
Routine PCR and qPCR testing.
Research & biotech
Reproducible experimental work.
Clinical molecular labs
Regulated infectious-disease & genetic testing.
Academic labs
Shared instrument reliability.
Public health labs
High-throughput amplification.
Pathology / molecular path
Companion diagnostics support.
PCR thermocycler calibration & preventive maintenance — common questions
How much does thermal cycler calibration cost?
Why calibrate a PCR thermocycler?
What does thermocycler calibration measure?
Do you also perform preventive maintenance?
How often should thermocyclers be calibrated?
Which instruments do you support?
Do you calibrate thermal cyclers on-site?
Is a thermal cycler the same as a thermocycler?
Verification for Applied Biosystems and Eppendorf platforms
Send your GeneAmp 9700 single-head or dual-head configuration, Veriti or Veriti Pro, SimpliAmp, ProFlex, or Eppendorf Mastercycler model. Include the installed block and serial number. The probe configuration, temperature set points and acceptance limits must fit the instrument and the agreed scope.
Accuracy, uniformity and heating performance
Temperature accuracy compares a measured value with its target. Uniformity examines differences across tested locations in the block. Ramp or heating performance, when included, evaluates behavior as temperatures change. A passing result for one measurement does not establish a pass for all of them.
What happens when an instrument fails verification?
Out-of-limit findings are documented rather than described as a passing calibration. We discuss the affected measurements and possible next steps. Your laboratory determines whether to restrict use, seek repair and arrange repeat verification. Thermal verification does not validate a PCR assay or certify qPCR optical performance.
Coordinate your laboratory services
Coordinate your laboratory service
Coordinate your molecular laboratory equipment in one service plan: pipette calibration, centrifuge RPM verification and electrical safety testing. Send your equipment list so we can confirm the scope.
Get your thermal cycler verification quote.
Tell us the equipment, make and model, and where it is. We'll reply within one business day with a quote and the earliest service date. No obligation.
Equipment-specific verification and reporting
Send the model, block configuration, instrument count and facility location. Verification covers the agreed temperature set points, block accuracy, uniformity and applicable model-specific functional tests. Acceptance criteria depend on the instrument and agreed scope. Thermal verification of the instrument is separate from clinical assay validation. If results fall outside the agreed limits, we document the findings and discuss the next steps.
Pipette calibration · Calibration and verification services · Puerto Rico service coordination