Calibration & verificationAll calibration servicesPipette calibrationCentrifuge / RPM verificationThermometer calibrationPCR thermocycler calibrationCO₂ incubator calibrationElectrical safety (NFPA 99)EKG / ECG certificationFume hood certificationBiosafety cabinet certificationClean room & USP 797 certificationEquipment service & repairLab equipment repairHistology & pathology serviceCryostat repair & PMScientific refrigerationEngineering & modernizationEmergency service & loanersRental & loaner instrumentsDecontamination & removalModels we serviceCompliance & lab setupInspection readinessService agreementsMohs lab equipmentCryostat Care PlanMohs staffing & risk managementLab setup & turnkey labsClient portal (coming soon)Free readiness checklistMedical offices & urgent careDental practicesGI & endoscopy centers Who we serveClinical laboratoriesMolecular & research labsPathology & Mohs labsIVF & fertility labsDermatology groupsMedical-center groupsCommunity health centersResidential & specialty careSee all facilities we serve Where we workMiami & Miami-DadeFort LauderdaleWest Palm BeachTampa BayOrlandoNaples & Fort MyersPuerto Rico MoreResourcesReviews Book a free assessment
Inspection Prep

Preparing your Mohs or pathology lab for a CAP inspection

BMCA Group · · 5 min read · Florida & Puerto Rico

For Mohs, dermatopathology, and histology labs, a CAP or CLIA inspection comes down to two things: are your processes sound, and can you prove your equipment is calibrated, maintained, and safe? The first is your domain. The second is where many labs lose points — and where a little preparation goes a long way.

The equipment-and-documentation checklist

Cryostat & histology bench

  • Current preventive-maintenance records for the cryostat and processors.
  • Temperature verification documented.
  • Decontamination and safety checks on file.

Calibration

  • Centrifuges, pipettes, and thermometers calibrated on schedule.
  • NIST-traceable certificates available on demand.
  • On-instrument labels showing last and next-due dates.

Electrical safety

  • Powered equipment safety-tested per NFPA 99, with documentation.

Cold storage

  • Refrigerators and freezers monitored, with calibrated probes and a clean record.

The 10-year rule

  • Under CLIA, pathology slides are retained for 10 years . Have your storage and retrieval plan documented — surveyors ask.

Survey day shouldn't be a fire drill. If your records are current and organized, it's just another day.

Where labs lose easy points

Almost always: documentation that exists somewhere but can't be produced quickly, a calibration that lapsed, or a piece of equipment that was never electrically safety-tested. None of these are hard to fix — they just need a system that keeps them current.

Make readiness continuous, not last-minute

The labs that breeze through inspections don't cram — they run a continuous program where calibration, PM, electrical safety, and documentation stay current year-round. That's the idea behind inspection readiness , and if you're setting up a new lab , it's far easier to build it in from day one than to retrofit it later.

Not sure where your equipment stands?

Request a free Compliance & Equipment Readiness Assessment — we’ll spot-check your gear and documentation and leave you a short report.

See where your lab stands — free.

Request a no-obligation Compliance & Equipment Readiness Assessment. We'll spot-check your equipment and documentation and leave you a short readiness report.

No obligation · we'll reply within one business day.
Prefer to talk? Call 305.238.5326
Free readiness assessment

Not sure where your lab actually stands?

We'll spot-check your equipment and documentation against what CLIA, CAP, and AHCA surveyors check, then leave you a short readiness report — no obligation, whether or not you ever work with us.

☎ 305.238.5326Free assessment